The ACI 305 nomograph
The ACI 305 nomograph estimates evaporativity: the peak rate at which the air can take water from a free water surface (Uno 1998). It is the industry tool to assess the environment during casting of slabs.
In 3D concrete printing, the environment is even more relevant. As 3DCP mixtures do not bleed water as a floor slab does, capillary pressure starts at once. In other words, the ideal evaporativity is zero. The nomograph reads the environment, and how far it is from that ideal. It is most useful as a way to forecast the need for curing and to compare printing conditions. This guide says how to read the figure, what to measure, and how far to trust the number.
Background
The environment has significant effects on concrete, specifically the availability of water for curing, and stresses caused by evaporation. In conventional casting, formwork protects most of the concrete, and in floor slabs bleeding water to the surface protects the rest. This is not true for 3D printed concrete.
Capillary pressure and relative volume changes, when constrained by the printbed or other layers, will often result in cracks. By controlling the environment you can minimize or delay these forces, so the concrete can build sufficient strength to withstand them.
How to read it
The nomograph is four panels, read clockwise from the top left. One construction line threads through all four, from the ambient temperature to the evaporation rate. Two carriers join the panels: the air moisture level and the moisture deficit. Each panel also draws both thresholds in its own input, so it says how far that input can move.
What to measure
The tool reads four inputs. Each is a value measured at the print, not a value assumed for the hall. A hall can carry 3 to 5 °C between floor and ceiling. So a sensor on the wall reads a different air from the fresh layer. The surface temperature is the input the equation is most sensitive to.
| Input | Unit | Range | Where to take the reading | What the tool accepts |
|---|---|---|---|---|
| Step 1Ambient temperature | °C | 5 to 40 | In the air beside the printhead, at the height of the fresh layer. | None. Enter the temperature you measured. |
| Step 2Relative humidity | % | 20 to 100 | In the same air as the temperature, clear of the door and of the mixer. | None. Enter the humidity you measured. |
| Step 3Surface temperature | °C | 5 to 40 | On the top of the layer just laid, with an infrared thermometer. | The printing temperature, which the control asks for. A face that evaporates cools below it. |
| Step 4Air movement | km/h | 0 to 25 | At the fresh layer, in the air that crosses its face. Fans, hoods and open doors all count. | A preset instead of a measurement. Indoor 2 km/h. Outdoor 8 km/h. Outdoor, windy 20 km/h. |
The model
Menzel (1954) measured the rate at which water leaves a free water surface under known air temperature, humidity and air movement. Uno (1998) fitted those measurements to one closed-form equation. This tool computes that equation with no correction for printing, so the chart stays the ACI 305 nomograph. Three assumptions travel with the equation, and each one fails at a printed face.
| Symbol | Meaning | Unit |
|---|---|---|
| E | Evaporation rate from the surface | kg/m²/h |
| Ts | Surface temperature of the fresh concrete | °C |
| Ta | Ambient temperature of the air | °C |
| r | Relative humidity divided by 100 | none |
| V | Air movement over the surface | km/h |
Accuracy and limits
The nomograph and its equations do not estimate the rate at which the concrete surface loses water. They estimate evaporativity: the peak rate at which the air can take water from a free water surface (Uno 1998). The nomograph therefore reads the environment, not the concrete. It is most useful as a way to forecast the need for curing and to compare printing conditions. On a cast surface, bleed water rises and keeps a film of free water on the face. That film holds the assumption behind the ACI limit: the equation matches the concrete only while bleed water covers the face.
A 3DCP mixture bleeds almost nothing. Without a water film, capillary pressure builds from the first minute at any evaporation rate. The strength of the layer must develop fast enough to take it. For the best structural performance, evaporativity should be zero. Capillary action drives a relative volume change in the drying layer, and stresses concentrate where that change is held. Three constraints can hold it: the printbed, a layer below that shrinks at a different rate, or a step in stiffness in the geometry. The 0.25 kg/m²/h working threshold comes from cracking evidence, not from the equation. Nobody holds the calibration data from vertical printed faces that would settle it.
Sources
Every figure on this page comes from one of these sources. Several are quoted as the named papers report them. The originals are named here so that a reader can check each one.
- ACI 305R, Guide to Hot Weather Concreting. American Concrete Institute. Source of the nomograph and the 1.0 kg/m²/h limit.
- ACI 308R-23, Guide to Curing Concrete. American Concrete Institute. The nomograph gives evaporativity, not the loss from concrete. Source of Menzel's measuring conditions, of the ±25 % up to 1.0 kg/m²/h, and of the overestimate above it.
- Menzel, C. A. (1954). Causes and prevention of crack development in plastic concrete. Portland Cement Association. The equation behind the nomograph.
- Uno, P. J. (1998). Plastic shrinkage cracking and evaporation formulas. ACI Materials Journal 95(4): 365-375. The closed-form equation used here, and the origin of the 1.0 limit.
- Al-Fadhala, M. and Hover, K. C. (2001). Rapid evaporation from freshly cast concrete and the Gulf environment. Construction and Building Materials 15(1): 1-7. The wind-tunnel work behind the ±25 %, and the fall in the loss after the bleed water.
- Moelich, G. M., Kruger, J. and Combrinck, R. (2020). Plastic shrinkage cracking in 3D printed concrete. Composites Part B 200: 108313. And (2022), the plastic-shrinkage crack-risk model, Cement and Concrete Composites.
- Markin, S., Combrinck, R. and Mechtcherine, V. (2023). Cement and Concrete Research, and preprint SSRN 4511047. Plastic shrinkage of printed concrete with and without formwork, and the effect of filament thickness.
- Deysel, Boshoff and Smit (2023). Implementing capillary pressure control measures to prevent plastic shrinkage cracking in concrete. Construction and Building Materials. The cracking evidence that brackets the 0.25 line.
- Slowik, V., Schmidt, M. and Fritzsch, R. (2008). Capillary pressure in fresh cement-based materials and identification of the air entry value. Cement and Concrete Composites 30(7): 557-565.